FQXSFPU0009K : An external clock frequency mismatch has been detected for one or more processors.

An external clock frequency mismatch has been detected for one or more processors.

Severity

Critical

Serviceable with log

No

Automatically Notify Support

No

User Action

Complete the following steps:\n1) Verify that the processor is a valid option that is listed as a Server Proven device for this system. If not, remove the Processor and install one listed on the Server Proven website.\n2) Verify that matching processors are installed in the correct processor sockets. Correct any mismatch found.\n3) Check Lenovo support site for an applicable service bulletin or firmware update that applies to this processor error.\n4) Replace the processor. Inspect the processor socket and replace the system board first if the socket is damaged.