GET /chassis/metrics/{uuid}

Use this method to return a set of sample metrics for specific chassis. Each sample is represented in terms of when the sample was taken (timeStamp) and the value of the sample (metricValue).

Authentication

Authentication with user name and password is required.

Request URL

GET https://{management_server_IP}/chassis/metrics/{uuid}

where {uuid} is the UUID of the chassis. To obtain the chassis UUID, use the GET /chassis method.

Query parameters

None

Request body

None

Response codes

Code Description Comments
200 OK The request completed successfully.
400 Bad Request A query parameter or request attribute is missing or not valid, or the operation is not supported. A descriptive error message is returned in the response body.
403 Forbidden The orchestrator server was prevented from fulfilling the request. A descriptive error message is returned in the response body. Ensure that you have privileges to perform the request.
409 Conflict There is a conflict with the current state of the resource. A descriptive error message is returned in the response body.
500 Internal Server Error An internal error occurred. A descriptive error message is returned in the response body.

Response body

Each energy metric contains one or more arrays that include when the sample was taken (timeStamp) and the value of the sample (metricValue).

Attributes Type Description
energyMetrics Object Energy metrics for the chassis
  averageSystemInputPower Array of objects Average system input power samples
  minimumSystemInputPower Array of objects Minimum system input power samples
  maximumSystemInputPower Array of objects Maximum system input power samples
  averageSystemOutputPower Array of objects Average system output power samples
  minimumSystemOutputPower Array of objects Minimum system output power samples
  maximumSystemOutputPower Array of objects Maximum system output power samples
  avgInletAirTemperature Array of objects Average inlet air temperature samples
  minInletAirTemperature Array of objects Minimum inlet air temperature samples
  maxInletAirTemperature Array of objects Maximum inlet air temperature samples
  coolingSubsystemAirFlow Array of objects Cooling subsystem air flow samples
  outletAirTemperature Array of objects Outlet air temperature samples
name String Chassis name
uuid String Chassis UUID
uri String Chassis URI
The following example is returned if the request is successful.
{
   "energyMetrics": {
      "averageSystemInputPower": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 616
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 617
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 620
      }],
      "minimumSystemInputPower": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 616
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 617
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 620
      }],
      "maximumSystemInputPower": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 616
      }...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 617
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 620
      }],
      "averageSystemOutputPower": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 548
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 553
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 566
      }],
      "minimumSystemOutputPower": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 548
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 553
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 566
      }],
      "maximumSystemOutputPower": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 548
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 553
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 566
      }],
      "avgInletAirTemperature": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 2550
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 2570
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 2570
      }],
      "minInletAirTemperature": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 2550
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 2550
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 2550
      }],
      "maxInletAirTemperature": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 2550
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 617
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 620
      }],
      "coolingSubsystemAirFlow": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 237
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 240
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 238
      }],
      "outletAirTemperature": [{
         "timeStamp": "2015-02-06T18:35:00Z",
         "metricValue": 3015
      },
      ...{
         "timeStamp": "2015-02-06T20:24:59Z",
         "metricValue": 3033
      },
      {
         "timeStamp": "2015-02-06T20:30:01Z",
         "metricValue": 3013
      }]
   },
   "name": "SN#Y011BG31R02F",
   "uuid": "3D1D5931BDF84D30ADA976E21F08CB91",
   "uri": "chassis/3D1D5931BDF84D30ADA976E21F08CB91"
}