Skip to main content

System requirements

This topic lists the system requirements for the Lenovo XClarity Integrator.

Prepare users’ environment

Lenovo XClarity Integrator is an extension of Windows Admin Center. It works in the same environment as Windows Admin Center. For more information, refer to Windows Admin Center and Install Windows Admin Center.

Supported software
Software typeSoftware version
Windows Admin Center2110, 2110.2, 2211, 2306, 2311
Lenovo XClarity Administrator3.0.0, 3.1.0, 3.1.1, 3.2.0, 3.3.0, 3.4.0, 3.5.0, 3.6.0, 4.0.x
Supported operating systems
Server typeWindows versionWindows Server versionAzure Stack HCI version

Management server

(installed with LXCI)

10, 112016, 2019, 2022/

Managed server

(managed by LXCI)

/2016, 2019, 202220H2, 21H2, 22H2, 23H2
Supported Web browser
Web browser typeWeb browser version
Google Chrome93.0.4577.82 or later versions
Microsoft Edge93.0.961.52 or later versions
Note
LXCI for WAC saves some settings in local database of the browser. To prevent the lost of the saved settings, do not clear cookies and site data.

Port requirements

Depending on the firewall in the environment, several ports should be available. If these ports are blocked or used by another process, some Lenovo XClarity Integrator functions might not work.

  • All out-bounding connections initialized from Windows Admin Center are allowed.

  • Lenovo XClarity Integrator does not require any additional in-bounding connections other than those required by Windows Admin Center.

Supported hardware

Supported hardware is listed in the following table.
Note

Some features are supported only by specific server models. Refer to Features supported by specific server models.

Table 1. Supported hardware
SystemServer models
Lenovo ThinkSystem
  • SD530 (7X20, 7X21, 7X22)

  • SD630 V2 (7D1K)

  • SD650 (7X58)

  • SD650 V2 (7D1M)

  • SD650-N V2 (7D1N)

  • SE350 (7Z46, 7D1X, 7D27, 7D1R)

  • SN550 (7X16)

  • SN550 V2 (7Z69)

  • SN850 (7X15)

  • SR150 (7Y54) (China only)

  • SR158 (7Y55)

  • SR250 (7Y51, 7Y52) (worldwide except India)

  • SR250 (7Y72, 7Y73) (India only)

  • SR250 V2 (7D7Q, 7D7R, 7D7S)

  • SR258 (7Y53)

  • SR530 (7X07, 7X08)

  • SR550 (7X03, 7X04)

  • SR570 (7Y02,7Y03)

  • SR590 (7X98,7X99)

  • SR630 (7X01,7X02)

  • SR630 V2 (7Z70, 7Z71)

  • SR630 V3 (7D72, 7D73, 7D74)

  • SR635 (7Y98, 7Y99)

  • SR635 V3 (7D9H, 7D9G)

  • SR645 (7D2X, 7D2Y)

  • SR645 V3 (7D9C, 7D9D)

  • SR650 (7X05, 7X06)

  • SR650 V2 (7Z72, 7Z73)

  • SR650 V3 (7D75, 7D76, 7D77)

  • SR655 (7Y00, 7Z01)

  • SR655 V3 (7D9E, 7D9F)

  • SR665 (7D2V, 7D2W)

  • SR665 V3 (7D9A, 7D9B)

  • SR670 (7Y36, 7Y37, 7Y38)

  • SR670 V2 (7Z22, 7Z23)

  • SR850 (7X18, 7X19)

  • SR850 V2 (7D31, 7D32, 7D33)

  • SR850 V3 (7D96, 7D97, 7D98)

  • SR850P (7D2F, 7D2G, 7D2H)

  • SR860 (7X69, 7X70)

  • SR860 V2 (7Z59, 7Z60, 7D42)

  • SR860 V3 (7D93, 7D94, 7D95)

  • SR950 (7X11, 7X12, 7X13)

  • ST250 (7Y45, 7Y46)

  • ST250 V2 (7D8F, 7D8G, 7D8H)

  • ST258 (7Y47)

  • ST550 (7X09, 7X10)

  • ST558 (7Y15, 7Y16) (China only)

  • ST650 V2/ST658 V2 (China only) (7Z74, 7Z75, 7Z76)

  • ST650 V3 (7D7A, 7D7B, 7D7C)

Lenovo ThinkAgile
  • MX Series appliance server (7D19, 7D1B, 7D2U, 7D5R, 7D5S, 7D5T, 7D6U, 7D6S, 7D66, 7D67, 7D6B, 7Z20)

  • SXM Series appliance server (9565, 7Y34)

Lenovo ThinkServer
  • nx360 M5 (5465)

  • sd350 M5 (5493)

Lenovo ThinkEdge
  • SE450 (7D8T)

  • SE455 V3 (7DBY)

Lenovo Flex System
  • x240 Compute Node(7162, 2588)

  • x240 M5 Compute Node (2591, 9532)

  • x440 Compute Node (7167, 2590)

  • x280, x480, x880 X6 Compute Node (7196, 4258)

Lenovo System x
  • x3250 M6 (3633, 3943)

  • x3500 M5 (5464)

  • x3550 M5 (5463, 8869)

  • x3630 M4 (8103)

  • x3650 M5 (8871, 5462)

  • x3750 M4 (8753)

  • x3850 X6 (6241)

  • x3950 X6 (6241)

Features supported by specific server models

The following table lists the features that are supported only by specific server models.

Table 2. Features supported by specific server models
FeatureServer models supporting the feature
Storage Spaces Direct (Azure Stack HCI) cluster disk management
  • ThinkAgile MX3520 appliance on SR650 (7D5R)

  • ThinkAgile MX certified node on SR650 (7Z20)

  • ThinkSystem SR650 (7X05, 7X06)

  • ThinkSystem SR650 V2 (7Z72, 7Z73)

  • ThinkSystem SR650 V3 (7D75, 7D76, 7D77)

System update with best recipes
  • ThinkAgile MX1020 appliance on SE350 (7D5S, 7D5T)

  • ThinkAgile MX1021 certified node on SE350 (7D1B, 7D2U)

  • ThinkAgile MX3330 appliance on SR630 V2 (7D19)

  • ThinkAgile MX3331 certified node on SR630 V2 (7D67)

  • ThinkAgile MX3530 appliance on SR650 V2 (7D6B)

  • ThinkAgile MX3531 certified node on SR650 V2 (7D66)

  • ThinkAgile MX3520 appliance on SR650 (7D5R)

  • ThinkAgile MX certified node on SR650 (7Z20)

  • ThinkAgile MX630 V3 (7D6U)

  • ThinkAgile MX650 V3 (7D6S)

Azure Stack HCI cluster deployment Note 1
  • ThinkAgile MX1020 appliance on SE350 (7D5S, 7D5T)

  • ThinkAgile MX1021 certified node on SE350 (7D1B, 7D2U)

  • ThinkAgile MX3330 appliance on SR630 V2 (7D19)

  • ThinkAgile MX3331 certified node on SR630 V2 (7D67)

  • ThinkAgile MX3520 appliance on SR650 (7D5R)

  • ThinkAgile MX3530 appliance on SR650 V2 (7D6B)

  • ThinkAgile MX3531 certified node on SR650 V2 (7D66)

  • ThinkAgile MX certified node on SR650 (7Z20)

  • ThinkAgile MX630 V3 (7D6U)

  • ThinkAgile MX650 V3 (7D6S)

  • ThinkSystem SE350 (7Z46, 7D1X, 7D27, 7D1R)

  • ThinkSystem SR630 V2 (7Z70, 7Z71)

  • ThinkSystem SR650 (7X05, 7X06)

  • ThinkSystem SR650 V2 (7Z72, 7Z73)

  • ThinkSystem SR650 V3 (7D75, 7D76, 7D77)

Cluster-Aware Updating (CAU) Note 1
  • ThinkAgile MX1020 appliance on SE350 (7D5S, 7D5T)

  • ThinkAgile MX1021 certified node on SE350 (7D1B, 7D2U)

  • ThinkAgile MX3330 appliance on SR630 V2 (7D19)

  • ThinkAgile MX3331 certified node on SR630 V2 (7D67)

  • ThinkAgile MX3520 appliance on SR650 (7D5R)

  • ThinkAgile MX3530 appliance on SR650 V2 (7D6B)

  • ThinkAgile MX3531 certified node on SR650 V2 (7D66)

  • ThinkAgile MX certified node on SR650 (7Z20)

  • ThinkSystem SE350 (7Z46, 7D1X, 7D27, 7D1R)

  • ThinkSystem SR630 V2 (7Z70, 7Z71)

  • ThinkSystem SR650 (7X05, 7X06)

  • ThinkSystem SR650 V2 (7Z72, 7Z73)

  • ThinkSystem SR650 V3 (7D75, 7D76, 7D77)

Native OS management Note 2 and 3All servers except for the ThinkServer or ThinkSystem SR635 (7Y98,7Y99)/SR655 (7Y00, 7Z01) servers.
Note
  1. The Microsoft Azure Stack HCI operating system must be used to support this feature.

  2. IPMI over KCS Access, Ethernet Over USB, and REST/CIM Over HTTPS must be enabled to support this feature.

  3. By default, native OS management is disabled for servers enabled with Storage Spaces Direct. Users can enable it by referring to Configuring native OS management.